The purpose of containment during remediation activities is to limit release of mold into the air and surroundings, in order to minimize the exposure of remediators and building occupants to mold. Mold and moldy debris should not be allowed to spread to areas in the building beyond the contaminated site.

The two types of containment recommended are limited and full. The larger the area of moldy material, the greater the possibility of human exposure and the greater the need for containment. In general, the size of the area helps determine the level of containment. However, a heavy growth of mold in a relatively small area could release more spores than a lighter growth of mold in a relatively large area. Choice of containment should be based on professional judgment. The primary object of containment should be to prevent occupant and remediator exposure to mold.

Limited Containment

Limited containment is generally recommended for areas involving between 10 and 100 square feet (ft 2 ) of mold contamination. The enclosure around the moldy area should consist of a single layer of 6-mil, fire-retardant polyethylene sheeting. The containment should have a slit entry and covering flap on the outside of the containment area. For small areas, the polyethylene sheeting can be affixed to floors and ceilings with duct tape. For larger areas, a steel or wooden stud frame can be erected and polyethylene sheeting attached to it. All supply and air vents, doors, chases, and risers within the containment area must be sealed with polyethylene sheeting to minimize the migration of contaminants to other parts of the building. Heavy mold growth on ceiling tiles may impact HVAC systems if the space above the ceiling is used as a return air plenum. In this case, containment should be installed from the floor to the ceiling deck, and the filters in the air handling units serving the affected area may have to be replaced once remediation is finished.

The containment area must be maintained under negative pressure relative to surrounding areas. This will ensure that contaminated air does not flow into adjacent areas. This can be done with a HEPA-filtered fan unit exhausted outside of the building. For small, easily contained areas, an exhaust fan ducted to the outdoors can also be used. The surfaces of all objects removed from the containment area should be remediated/cleaned prior to removal. The remediation guidelines can be implemented when the containment is completely sealed and is under negative pressure relative to the surrounding area.

Full Containment

Full containment is recommended for the cleanup of mold-contaminated surface areas greater than 100 ft 2 or in any situation in which it appears likely that the occupant space would be further contaminated without full containment. Double layers of polyethylene should be used to create a barrier between the moldy area and other parts of the building. A decontamination chamber or airlock should be constructed for entry into and exit from the remediation area. The entryways to the airlock from the outside and from the airlock to the main containment area should consist of a slit entry with covering flaps on the outside surface of each slit entry. The chamber should be large enough to hold a waste container and allow a person to put on and remove PPE. All contaminated PPE, except respirators, should be placed in a sealed bag while in this chamber. Respirators should be worn until remediators are outside the decontamination chamber. PPE must be worn throughout the final stages of HEPA vacuuming and damp-wiping of the contained area. PPE must also be worn during HEPA vacuum filter changes or cleanup of the HEPA vacuum.

Containment Tips

  • Always maintain the containment area under negative pressure
  • Exhaust fans to outdoors and ensure that adequate makeup air is provided.
  • If the containment is working, the polyethylene sheeting should billow inwards on all surfaces. If it flutters or billows outward, containment has been lost, and you should find and correct the problem before continuing your remediation activities.

Courtesy of the EPA

Plan Remediation - Sampling - Protective Equipment - Hidden Mold - Clean-Up - Investment Remediation - Containment - Finsh








member comments

or Register to leave a comment.

If you have a question you would like answered, please visit our Community Forums.

Related Articles

Answers to Mold Cleaning Questions
Answers to members' questions about cleaning household mold... read more

Moisture and Mold Problems - Sampling
Investigating, Evaluating, and Remediating Moisture and Mold Problems: Sampling... read more

Mold Remediation in Schools and Commercial Buildings - Checklist
Mold Remediation in Schools and Commercial Buildings: Checklist for Mold Remediation... read more

articles we like

Mental Health Care
Mental health care is available most everywhere. Services are offered at low cost centers... read more

Customize Your Window Treatments
Custom window treatments let you coordinate the style, pattern and color of your window treatments... read more

Learning Your Way to a New Career
Millions of people feel stuck in a rut every year and turn to education to... read more

sponsored articles of the day

diy centers

Research and explore a wealth of wisdom on these topics